Goyen Type 2" Inlet 1-1/2" Outlet Flanged Pneumatic Pulse Valve for Dust Collector Systerm

Brand Name : Brando

Model Number : CA45FS

Certification : CE

Place of Origin : China

MOQ : 1 pc

Payment Terms : L/C, T/T, Western Union

Supply Ability : 100000pcs per month

Delivery Time : Negotiation

Packaging Details : inner boxes,cartons,pallets

Outlet Size : 1-1/2'' outlet

Inlet Size : 2''

Power : Solenoid

Structure : Diaphragm

Working Medium : Air

Working Pressure : 0.3~0.8Mpa

Working Temperature : -5℃~+55℃

Voltage : AC24V, AC110V, AC220V, DC24V

Temperature of media : AC220V, AC110V, AC24V, DC24V

Price : Negotiation

Contact Now

Goyen Type 2'' Inlet 1-1/2'' Outlet Flanged Pneumatic Pulse Valve for Dust Collector Systerm

Goyen Type Flanged dust collector pulse valve with diecast aluminum alloy body, wiedely used in baghouse . Baghouse are the most versatile dust collector style and can be used in all applications. Baghouse collectors with traditional bag filters are preferred for applications with larger or mixed range of dust particle sizes, heavier dust loading, fibrous/sticky dusts or higher temperatures (normally up to 550F, in some cases up to 750F with specialty fabrics).

The working principle :The high-pressure gas enters from the air inlet and enters the lower air chamber.
1. When the pulse valve is not powered, the gas enters the decompression chamber through the constant-pressure pipe on the upper and lower shells and the throttle hole therein. Because the valve plug blocks the pressure relief hole under the action of the spring, the gas will not be discharged. Make the pressure in the decompression chamber and the lower air chamber consistent, and under the action of the spring, the diaphragm will block the injection port, and the gas will not burst out.
2. When the pulse valve is energized, the valve core is lifted up by the electromagnetic force, the pressure relief hole is opened, and the gas is ejected. Due to the role of the orifice of the constant pressure pipe, the throughput of the pressure relief hole is greater than The flow velocity of the pressure pipe gas makes the pressure in the decompression chamber lower than the pressure in the lower chamber. The gas in the lower chamber lifts the diaphragm, opens the blowing port, and performs gas blowing.


Technical Data of CA45FS Flanged Valve:

Model No CA45FS
Port Size

1-1/2'' Outlet 2'' Inlet

Valve Type

Diaphragm Valve

Action Type

Pilot Operated

Connection Type

Flanged Inlet Port

Temperature Range

-5℃~+55℃

Pressure 0.3~0.8Mpa
Body Material Diecast Aluminum Alloy
Seal Material NBR(common, all available)
Voltage AC24V, AC110V, AC220V, DC24V

Main Dimension of CA45FS double diaphragm pulse valve:

Goyen Type 2" Inlet 1-1/2" Outlet Flanged Pneumatic Pulse Valve for Dust Collector Systerm

Details About CA45F​S Electromagentic Pulse Valve:

Goyen Type 2" Inlet 1-1/2" Outlet Flanged Pneumatic Pulse Valve for Dust Collector Systerm

Construction of CA45FS:

Body: Diecast aluminum
Ferrule: 305 SS
Armature: 430FR SS
Seals: Nirtrile or FKM
Spring: 304 SS
Screws: 302 or 304 SS
Outlet Slide Seal: EPDM or FKM
Diaphragm Seat: PA-66(standard). FKM coated mild steel

Connection Surface of CA45FS Diaphragm Pulse Valve:

Goyen Type 2" Inlet 1-1/2" Outlet Flanged Pneumatic Pulse Valve for Dust Collector Systerm

INSTALLATION of CA45FS AC220V AC110V AC24V DC24V Solenoid Pulse Valve:

1. Prepare inlet flanges and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet flange and blowtube to valves with all seals in place. Tighten flange bolts to 10Nm (7.4 ft–lbs) Ensure blowtube is pushed all the way into the valve outlet.
5. Tanks and pipes must be independently supported from valve.
6. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
7. Apply moderate pressure to system and check for installation leaks.
8. Fully pressurise system.
9. Test fire and listen for proper actuation and crisp pulse noise.Valve is not a structural component. Do not rely on valve to retain tanks or pipe. Where used, refer to product specification for installation details.

Welcome to your any question and inquiry!


Product Tags:

Goyen Pulse Valve

      

Goyen Diaphragm Valve

      

Goyen Solenoid Valve

      
Quality Goyen Type 2" Inlet 1-1/2" Outlet Flanged Pneumatic Pulse Valve for Dust Collector Systerm wholesale

Goyen Type 2" Inlet 1-1/2" Outlet Flanged Pneumatic Pulse Valve for Dust Collector Systerm Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Brando Hardware Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)