Sign In | Join Free | My qualitytoyschina.com
China Ningbo Brando Hardware Co., Ltd logo
Ningbo Brando Hardware Co., Ltd
Focus on your demands Offer you best solution
Verified Supplier

10 Years

Home > Pulse Jet Valve >

BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S

Ningbo Brando Hardware Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S

Brand Name : Brando

Model Number : DMF-Z-62S

Certification : CE

Place of Origin : China

MOQ : 1 pc

Payment Terms : L/C, T/T, Western Union

Supply Ability : 100000pcs per month

Delivery Time : Negotiation

Packaging Details : inner boxes,cartons,pallets

Port Size : 2-1/2 Inch

Nominal Diametrer(mm) : Φ62

Number Of Diaphragm : 2

Power : Solenoid

Structure : Diaphragm

Blowing Area : 27 - 38㎡

Working Temperature : -25℃ to +80℃

Pressure : 0.1- 0.8MPa

Price : Negotiation

Contact Now

BFEC Type Right Angle 2-1/2'' Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S

This valve below is DMF-Z-62S right angle type solenoid pulse jet valve with die-casting aluminum alloy body. It simplifies the connection between gas bag and blowing tube of a dust collector. It can provide stronger airflow and meet dust removing requirements.

The high-pressure gas enters from the air inlet , enters the lower air chamber.

1. When the pulse valve is not energized, the gas enters the decompression chamber through the impulse valve and the orifice in the constant pressure pipeline on the upper and lower shells. The valve core blocks the pressure relief hole under the action of the spring. The gas will not be discharged, so that the pressure in the decompression chamber and the lower air chamber are consistent. Under the action of the spring, the diaphragm will block the injection port, and the gas will not burst out.

2. When the pulse valve is energized, the valve core is lifted upward by the electromagnetic force, the pressure relief hole is opened, and the gas is ejected. Due to the role of the orifice of the constant pressure pipe, the outflow speed of the pressure relief hole is greater than that of the decompression chamber. The inflow speed of the pressure pipe gas makes the pressure in the decompression chamber lower than the pressure in the lower chamber. The gas in the lower chamber lifts up the diaphragm, opens the injection port, and performs gas injection.

Specification Of DMF-Z-62S Electromagnetic Pulse Jet Valve:

Model Number DMF-Z-62S
Port Size G2-1/2''
Number of Diaphragm 2
KV/CV 129.26/150.85
Media Clean Air
Voltage AC220V, C110V, C24V, DC24V
Connection Type Thread
Relative Humidity of Air ≤85%
Seal Material NBR, HNBR, FKM, EPDM, Silicone, All Available
Body Material Aluminum Alloy

Overall Diemension

BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S

Deconstruction Diagram

BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S

Flow Direction Of DMF-Z-62S:

BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S

FAQ:

1.During installation and commissioning

1). The valve cannot be opened, but the pilot is operating. → Check if the airbag pressure is too low → Exclude air leaks.

2). Some valves are not working, others are normal.→Check the valve's wiring link and solenoid coil. → Replacement of accessories.

3). The valve cannot be closed and there is a leak, pressure cannot be established. → The inlet of the valve is installed opposite the injection port. → reassemble

4). The valve cannot be closed and there is a leak. → Impurities are adsorbed on the diaphragm, and the iron core is stuck. →Clean the diaphragm, check whether the diaphragm is complete, check the iron core, and replace the parts in time.

2.During use

1). Valve closes slowly. → Diaphragm orifice blocked. →Dredge orifice.

2). Some valves leak, the diaphragm does not close,normally opened. → Impurities are adsorbed on the diaphragm, the pilot is damaged, and the iron core is stuck. → Clean the diaphragm, check whether the diaphragm is complete, check the iron core, and replace the parts in time.

3). The coil is hot and burned. → Power on for a long time. → Check the working condition of the control system.

4). There is voltage but the valve is not working. → Damaged diaphragm or blocked orifice. → Replace parts in time.

5). Low ambient temperature, the valve is leaking or cannot be opened. → Ambient temperature is too low, there is icing in the valve. → Note the valve operating temperature range.

Welcome to your any question and inquiry!


Product Tags:

BFEC Pulse Valve

      

BFEC Diaphragm Valve

      

BFEC Solenoid Valve

      
Quality BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S wholesale

BFEC Type Right Angle 2-1/2" Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Brando Hardware Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)